Products

Battery Comprehensive Testers 120V (60/200A)

Technical Description

Key Features of  Battery Comprehensive Testers 120V (60/200A) Technical Parameters:

Voltage range (0-120V) Resolution 1mV Accuracy 1% RD+0. 1FS

Internal resistance range (0-2000 milliohms) resolution 001 milliohms accuracy 0.1% RD+0. 1FS

Charging Current (0-60A) Resolution 001 A Accuracy 0.1% RD+0. 1FS

Discharge current (0-200A) at the highest voltage, continuous discharge current 120A, resolution 0.001 A, accuracy 1% RD+0. 1FS (if customers have higher current requirements can be customized)

Overcurrent Delay Time (0-30S) Resolution 1mS Accuracy 1% RD+0. 1FS

Short circuit time (0-2000 μ s) resolution 1 μ s (microsecond) accuracy 1% RD+0. 1FS

NTC Range (0-100K) 001 K

R1 range (0-100K) 001 K

Operating voltage AC (200V-240V)

The maximum charging power is 2 W (when charging at the maximum current)

The maximum working power of discharge is 24 kW (when discharging at the maximum current)

Surge voltage < 15V

 

Key Fixture Features

Programmable DC supply and electronic load

Measurement of OCV and AC internal resistance

Charge/discharge profiling with over‑/under‑protection tests

Short‑circuit protection timing and delay tests

SN/barcode test initiation and automated workflows support