Key Features of Battery Comprehensive Testers 120V (60/200A) Technical Parameters:
Voltage range (0-120V) Resolution 1mV Accuracy 1% RD+0. 1FS
Internal resistance range (0-2000 milliohms) resolution 001 milliohms accuracy 0.1% RD+0. 1FS
Charging Current (0-60A) Resolution 001 A Accuracy 0.1% RD+0. 1FS
Discharge current (0-200A) at the highest voltage, continuous discharge current 120A, resolution 0.001 A, accuracy 1% RD+0. 1FS (if customers have higher current requirements can be customized)
Overcurrent Delay Time (0-30S) Resolution 1mS Accuracy 1% RD+0. 1FS
Short circuit time (0-2000 μ s) resolution 1 μ s (microsecond) accuracy 1% RD+0. 1FS
NTC Range (0-100K) 001 K
R1 range (0-100K) 001 K
Operating voltage AC (200V-240V)
The maximum charging power is 2 W (when charging at the maximum current)
The maximum working power of discharge is 24 kW (when discharging at the maximum current)
Surge voltage < 15V
Key Fixture Features
Programmable DC supply and electronic load
Measurement of OCV and AC internal resistance
Charge/discharge profiling with over‑/under‑protection tests
Short‑circuit protection timing and delay tests
SN/barcode test initiation and automated workflows support