Products

Battery Charge Discharge System 60V/75V/100V/120V (20A – 200A)

Technical Description

Key Features of Battery Charge Discharge System 60V/75V/100V/120V (20A – 200A)

Equipment model BCDS-V 100V 100A-1CH

Communication TCP/IP (so)

Channel control Single point independent control

Charging 80%

Charging voltage 0 ~ 100 v

Port discharge 12.5 ~ 100V

Charging current 0.02 A ~ 100 A

Discharge 75%

Discharge current 0.1 A ~ 100 A

Voltage accuracy ± (0.05%RD + 0.05%FS)

Accuracy of ± (0.1%RD + 0.05%FS)

Main According to the specific equipment, it can be customized and equipped with 1 channel for each

Voltage 1mV

Current 1mA

Temperature resolution 0.1 ℃

The input power AC 220V±10%/50Hz (Power supply mode for cabinet: three-phase five-wire)

Sampling time Sampling frequency of a single box is 10mS

Recording time 100mS~65535S

Charging mode Constant-current voltage limiting, constant-current voltage, constant-power charging, constant-current charging test (for batteries with protection plates)

Charge cut-off condition Voltage, current, time, capacity, temperature

Discharge patterns Constant current discharge, constant power discharge, constant current discharge test (for batteries with protection plates)

Discharge cut-off condition Voltage, current, time, capacity, temperature

Number of working steps per cycle 100 steps with nested loops (10 layers)

Circuit structure Modular design for easy replacement and maintenance

Software and hardware protection Reverse connection protection, over voltage protection, over current protection, over temperature protection, under voltage protection, short circuit protection

      Main System Functions The software supports all kinds of continuation, such as manual suspension, software shutdown continuation, power interruption continuation, equipment communication interruption continuation, abnormal stop continuation. Support bar code scanning, can scan one-dimensional code, two-dimensional code, sequence scanning, channel hopping scanning, disk scanning and other scanning methods. Local test detailed data storage, you can view the current test data and historical data of each channel at any time, data and curve corresponding two ways to present, and support to export EXCE report in the form of single or batch, in addition, according to the need to set the automatic derivative data at the end of the test. Support capacity sorting, can be graded battery sorting and LED light. Support the Pass judgment at the end of the test, according to the specified cycle capacity, voltage, time and other information to judge the Pass/NG result. Support all kinds of working step protection and global voltage, current, temperature abnormal protection, and abnormal alarm, support battery pack overcharge, over discharge protection test. Support unit conversion Support database server background MES storage or other MES docking Offline protection of hardware and software. Support channel parallel function Voltage acquisition and real-time screening, check the battery crimp before the test, and turn into voltage screening after the test. BMS communication protocol is connected, and battery charging and discharging steps are monitored through BMS data items.